Do not touch the orifice and essential to use particle free gloves. Before installation of the new aperture ensure it is clean and the orifice inlet is clear of debris.
#BECKMAN COULTER N5 MANUAL TRANSMISSION INSTALL#
#BECKMAN COULTER N5 MANUAL TRANSMISSION SERIES#
The dispenser has a nozzle to which a syringe filter or series of syringe filters can be fitted to remove any stray particles and ensure the cleanest possible electrolyte solution for use with the sample.
![beckman coulter n5 manual transmission beckman coulter n5 manual transmission](https://www.researchgate.net/profile/Moustafa-Ahmed-11/publication/308673698/figure/fig6/AS:410936214081537@1474986236047/Figure-15-Beckman-Coulter-Particle-Size-Analyzer-N5-submicron-particle-size-analyzer.png)
(For convenience a 2 L bottle of Isoflow pn 8547008 can be used). We recommend the use of a graduated dispenser, pn 8320309, which fits different bottles to dispense the isoton II electrolyte solution. Guidance for filtering Isoton and electrolyte solutions In addition the instrument should be thoroughly cleaned as recommended in chapter 4 of the User’s manual. Locating the instrument in a controlled environment such as a laminar flow hood (low airborne particulate levels and reduced electrical noise) is highly recommended. The steps outlined below, while fundamental in nature, become increasingly important when employing the smaller apertures. It is necessary to take some proactive steps to ensure a smooth and accurate testing process when working with smaller apertures. Many of these particles may come from random dust and other contaminating materials in the instrument environment. Using aperture tubes below 30 μm on a Multisizer instrument can be challenging due to the small size of the aperture which becomes easily clogged by larger particles. Additional information for changing and working with small size apertures is given in Chapter 4 of the User’s manual. The purpose of this application note is to provide some guidelines to facilitate successful testing with the Multisizer 4e when employing 30 µm and smaller.